| DC FIXED FREQUENCY | JP/GW-26CH(R) | JP/GW-35CH(R) | JP/GW-50CH(R) | JP/GW-70CH(R) | ||
| Rated Power supply | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | 1Ph / 220-240V/50Hz | ||
| Workable Power supply | 1Ph / 185-260V/50Hz | 1Ph / 185-260V/50Hz | 1Ph / 185-260V/50Hz | 1Ph / 185-260V/50Hz | ||
| Cooling | Capacity (btu/h) | 9000 | 12000 | 18000 | 24000 | |
| Capacity (W) | 2500(150~3000)W | 3500(150~3600)W | 5300(1250-5910) | 7300(1830~7800) | ||
| Input (W) | 900(100~1200)W | 1180(75~1560)W | 1780(330-2340) | 2350(410~2830) | ||
| Rated current (A) | 4.10 | 5.30 | 7.80 | 10.70 | ||
| EER | 2.70 | 2.80 | 2.84 | 2.90 | ||
| Heating | Capacity (btu/h) | 9000 | 12000 | 18000 | 24000 | |
| Capacity (W) | 2800(150~3300)W | 3700(150~3900)W | 5600(1250-6070) | 7600(1850~7900) | ||
| Input (W) | 960(75~1260)W | 1260(75~1580)W | 1670(340-2520) | 2240(420~3000) | ||
| Rated current (A) | 4.10 | 5.30 | 7.80 | 10.70 | ||
| COP | 2.90 | 2.80 | 2.85 | 2.90 | ||
| Max. input consumption (W) | 1300 | 1750 | 2500 | 3000 | ||
| Max. current (A) | 5.8 | 7.9 | 11.6 | 13.9 | ||
| Compressor | Type | Rotary | Rotary | Rotary | Rotary | |
| Brand | GMCC,GREE | GMCC,GREE | GMCC,GREE | GMCC,GREE,HIGHLY | ||
| Indoor unit | Indoor Coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, inner Grooved | φ7mm, inner Grooved | φ7mm, inner Grooved | φ7mm, inner Grooved | ||
| Indoor air flow (Turbo/Hi/Mi/Lo) (M3/h) | 500/450/370/320 | 550/450/370/320 | 850/750/650/580 | 1050/950/800/680 | ||
| Rated input Power(cooling/heating) (W) | 10 | 13 | 35 | 45 | ||
| Rated current (cooling/heating) (A) | 0.2 | 0.2 | 0.35 | 0.4 | ||
| Moisture Removal (KG/h) | 0.8 | 1.1 | 2 | 2.6 | ||
| Noise level(Turbo/Hi/Mi/Lo) (dB(A)) | 39/34/32/30 | 40/35/32/30 | 45/42/39/37 | 49/47/45/42 | ||
| Unit dimension (W*H*D) | 695×275×190 | 780×275×190 | 910×295×205 | 955×335×230 | ||
| Packing (W*H*D) | 763×322×241 | 847×322×241 | 975×340×255 | 1020×400×300 | ||
| Net weight (KGs) | 6 | 6.5 | 9 | 11 | ||
| Gross weight (KGs) | 8 | 8.5 | 11 | 14 | ||
| Outdoor unit | Outdoor coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, Inner Grooved | φ7mm, Inner Grooved | φ7mm, Inner Grooved | φ7mm, Inner Grooved | ||
| Noise level (dB) | 50 | 52 | 55 | 59 | ||
| Unit dimension (W*D*H) (mm) | 670(610)×295×495 | 780(710)×295×495 | 800(730)×305×550 | 850(780)×350×600 | ||
| Packing (W*D*H) (mm) | 704×324×530 | 818×328×530 | 835×340×580 | 896×387×625 | ||
| Net weight (KGs) | 19 | 23 | 30 | 34.5 | ||
| Gross weight (KGs) | 22 | 26 | 33 | 38.5 | ||
| Refrigerant type | R410A | R410A | R410A | R410A | ||
| Refrigerant pipe | Liquid side (mm) | Φ6 | Φ6 | Φ6 | Φ6 | |
| Gas side (mm) | Φ9 | Φ9 | Φ12 | Φ12 | ||
| Max. refrigerant pipe length (m) | 10 | 10 | 10 | 15 | ||
| Max. difference in level (m) | 5 | 5 | 5 | 10 | ||
| Operation temperature range | -7℃-43℃ | -7℃-43℃ | -7℃-43℃ | -7℃-43℃ | ||
| Ambient temperature range | -7℃-48℃ | -7℃-48℃ | -7℃-48℃ | -7℃-48℃ | ||
| Application area (MM2) | 10~17 | 13~27 | 20~40 | 30~55 | ||
| Sets per 40ft HQ/20ft | 382/167 | 334/143 | 280/133 | 196 / - | ||
Ductless wall split Air Conditioners have gained immense popularity in recent years, particularly in urban settings where space is a constraint. These units offer an efficient and flexible cooling solution without the need for extensive ductwork. Ideal for both residential and commercial spaces, they allow users to enjoy personalized comfort levels while reducing energy consumption.
OEM and ODM Services in China
In China, numerous manufacturers specialize in providing OEM (Original Equipment Manufacturer) and ODM (Original Design Manufacturer) services for ductless wall split Air Conditioners. This capability allows companies to produce customized products according to specific client requirements. Thus, brands can leverage local expertise to design and manufacture air conditioning solutions that meet the diverse needs of various markets.
Benefits of Ductless Systems
- Energy Efficiency: Ductless systems are known for their high SEER (Seasonal Energy Efficiency Ratio) ratings, which contribute to lower electricity bills.
- Flexible Installation: Without the need for ductwork, these units can be installed in a variety of configurations, making them suitable for different room layouts.
- Individual Zone Control: Each indoor unit operates independently, allowing occupants to set different temperatures in different areas.
- Improved Indoor Air Quality: Ductless systems often include advanced filtration systems that help to reduce allergens and improve overall air quality.
The Manufacturing Process
When it comes to manufacturing ductless wall split Air Conditioners, several critical steps are involved. Initially, engineers work on designing the units, focusing on aspects such as efficiency, aesthetics, and functionality. Following this, prototypes are developed and undergo rigorous testing to ensure compliance with international standards.
Once approved, the mass production phase begins. In many Chinese factories, automated machinery works alongside skilled labor to assemble components, including compressors, evaporators, and condensers. Quality assurance processes are implemented at various stages to mitigate defects, ensuring that every unit meets the specified performance criteria.
Market Trends and Innovations
The demand for ductless wall split air conditioners continues to grow, driven by advancements in technology and changing consumer preferences. Manufacturers are increasingly integrating smart technologies into their products, enabling features such as remote control via mobile apps, programmable timers, and real-time monitoring of energy consumption.
Moreover, environmental concerns have prompted many manufacturers to explore environmentally friendly refrigerants and energy-saving designs. As a result, the market is witnessing a shift towards more sustainable options that do not compromise on performance.
Choosing the Right Manufacturer
Selecting the right OEM/ODM partner in China is crucial for businesses looking to enter the ductless air conditioner market. Companies should consider factors such as the manufacturer's experience, product range, production capacity, and commitment to quality standards. Additionally, visiting the factory can provide valuable insights into their operational capabilities and adherence to safety regulations.
Conclusion
As global demands for efficient and adaptable air conditioning solutions rise, ductless wall split air conditioners place themselves at the forefront of the HVAC industry. With reputable Chinese manufacturers offering comprehensive OEM and ODM services, brands can effectively navigate the complexities of market entry and capitalize on emerging opportunities.