China Company Hotel Wall Split Air Conditioning Unit OEM/ODM

DC INVERTER (R410A,T3)JAUS-12C73RVE1-760A(BpT5C8)JAUS-12H73RVE1-760A(BpT5C7)JAUS-18C73RVF1-780(BpT5C6)
Rated Power supply1Ph / 230V/60Hz/50Hz1Ph / 230V/60Hz/50Hz1Ph / 230V/60Hz
Workable Power supply1Ph / 198-264V/60Hz/50Hz1Ph / 198-264V/60Hz/50Hz1Ph / 198-264V/60Hz
Cooling T1Capacity  (btu/h)120001200018000
Capacity  (W)352035205280
Input  (W)100010001510
Rated current  (A)4.50 4.50 6.80 
EER(Btu/h/W/W)12.01 12.01 11.90 
SEER(Btu/h/W/W)15.00 15.00 14.60 
Cooling T3Capacity  (btu/h)114001140016700
Capacity  (W)335033504900
Input  (W)120012001900
Rated current  (A)5.40 5.40 8.50 
EER(Btu/h/W/W)9.38 9.38 8.79 
EER(W/W)2.75 2.75 2.58 
HeatingCapacity  (btu/h)/14600/
Capacity  (W)/4290/
Input  (W)/1360/
Rated current  (A)/6.10 /
COP(Btu/h/W/W)/10.76 /
COP(W/W)/3.15 /
Max. input consumption   (W)168016802260
Max. current  (A)8.68.611.6
CompressorTypeRotaryRotaryRotary
BrandGMCC,LAMDAGMCC,LAMDAGREE
Indoor unitIndoor CoilFin materialGolden& hydrophilicGolden& hydrophilicGolden& hydrophilic
Tube outside dia.and materialφ7mm, inner Groovedφ7mm, inner Groovedφ7mm, inner Grooved
Indoor air flow (Hi/Mi/Lo)  (M3/h)850/750/650/580850/750/650/5801050/950/800/680
Rated input Power(cooling/heating)  (W)353545
Rated current  (cooling/heating)  (A)0.350.350.4
Moisture Removal  (KG/h)1.01.01.8
Noise level(Hi/Mi/Lo)  (dB)43/39/37/3343/39/37/3346/42/39/37
Unit dimension (W*H*D)910×295×205910×295×2051075×330×240
Packing (W*H*D)980×350×250980×350×2501150×415×330
Net weight  (KGs)101014
Gross weight  (KGs)121217
Outdoor unitOutdoor coilFin  materialGolden& hydrophilicGolden& hydrophilicGolden& hydrophilic
Tube outside dia.and materialφ7mm, Inner Groovedφ7mm, Inner Groovedφ5mm, Inner Grooved
Noise level  (dB)525255
Unit dimension (W*H*D)   (mm)830(760)×305×550830(760)×305×550850(780)×350×600
Packing   (W*H*D)  (mm)869×339×593869×339×593896×387×625
Net weight  (KGs)242529 
Gross weight  (KGs)272833
Refrigerant typeR410AR410AR410A
Refrigerant pipeLiquid side  (mm)Φ6Φ6Φ6
Gas side  (mm)Φ9Φ9Φ12
Max. refrigerant pipe length (m)101010
Max. difference in level  (m)555
Operation temperature range-7℃-52℃16℃-52℃16℃-52℃
Ambient temperature range-7℃-55℃16℃-55℃16℃-55℃
Application area   (MM2)13~2813~2820~40
Sets per 40ft HQ/20ft267/-267/-186/-

When it comes to hotel management, ensuring guest comfort is key. One way to achieve that is through efficient climate control systems, particularly using wall split air conditioning units. These units have gained popularity for their ability to provide targeted cooling in individual rooms, making them ideal for various settings, including hotels.

Why Choose Wall Split AC Units?

Wall split air conditioning units offer a host of benefits that can enhance the overall guest experience. Here are some of the standout features:

  • Energy Efficiency: These systems are designed to use minimal energy while maximizing cooling power, which translates to lower utility bills.
  • Quiet Operation: Unlike traditional window units, wall splits operate quietly, ensuring that guests enjoy a peaceful environment.
  • Easy Installation: With less invasive installation processes, wall split units can be set up quickly without major renovations.

OEM/ODM Services for Custom Solutions

For businesses looking to differentiate themselves, Original Equipment Manufacturer (OEM) and Original Design Manufacturer (ODM) services are invaluable. Partnering with a China company specializing in these services can lead to tailored solutions that meet specific client needs.

  • Customization: Manufacturers can produce units with unique designs, branding, and functionalities.
  • Cost-Effectiveness: By sourcing from China, companies can reduce production costs significantly.
  • Quick Turnaround Times: China's robust manufacturing infrastructure often allows for quicker production and delivery schedules.

The Role of Technology in Modern AC Systems

Modern wall split air conditioning units are more than just simple cooling devices; they incorporate advanced technology that enhances performance and user convenience. Smart features such as remote control operation, app connectivity, and programmable timers are becoming standard.

This technological evolution means greater control over room temperatures, which is beneficial not only for guests but also for energy management within the hotel. Installing a system from a reputable brand like Pazoeoeic Air Conditioner could provide these advanced features, further increasing its appeal.

Maintenance: Keeping Your AC Units Running Smoothly

Regular maintenance is crucial to ensuring that wall split AC units function efficiently over time. Hotel management should establish a routine check-up schedule, focusing on:

  • Cleaning or replacing filters regularly to maintain air quality.
  • Checking refrigerant levels to ensure optimal cooling performance.
  • Inspecting electrical components and connections to prevent any operational failures.

By being proactive about maintenance, hotels can extend the lifespan of their air conditioning systems and avoid costly repairs.

Conclusion: Making Informed Choices

Investing in wall split air conditioning units, especially through OEM/ODM partnerships, can significantly enhance the comfort levels within hotels. Not only do they provide excellent cooling solutions, but they also allow for customization and adaptability to the ever-changing hospitality market. The right choice in equipment can lead to satisfied guests, positive online reviews, and ultimately, repeat business.