| DC INVERTER (R410A,T3) | JAUS-12C73RVE1-760A(BpT5C8) | JAUS-12H73RVE1-760A(BpT5C7) | JAUS-18C73RVF1-780(BpT5C6) | ||
| Rated Power supply | 1Ph / 230V/60Hz/50Hz | 1Ph / 230V/60Hz/50Hz | 1Ph / 230V/60Hz | ||
| Workable Power supply | 1Ph / 198-264V/60Hz/50Hz | 1Ph / 198-264V/60Hz/50Hz | 1Ph / 198-264V/60Hz | ||
| Cooling T1 | Capacity (btu/h) | 12000 | 12000 | 18000 | |
| Capacity (W) | 3520 | 3520 | 5280 | ||
| Input (W) | 1000 | 1000 | 1510 | ||
| Rated current (A) | 4.50 | 4.50 | 6.80 | ||
| EER(Btu/h/W/W) | 12.01 | 12.01 | 11.90 | ||
| SEER(Btu/h/W/W) | 15.00 | 15.00 | 14.60 | ||
| Cooling T3 | Capacity (btu/h) | 11400 | 11400 | 16700 | |
| Capacity (W) | 3350 | 3350 | 4900 | ||
| Input (W) | 1200 | 1200 | 1900 | ||
| Rated current (A) | 5.40 | 5.40 | 8.50 | ||
| EER(Btu/h/W/W) | 9.38 | 9.38 | 8.79 | ||
| EER(W/W) | 2.75 | 2.75 | 2.58 | ||
| Heating | Capacity (btu/h) | / | 14600 | / | |
| Capacity (W) | / | 4290 | / | ||
| Input (W) | / | 1360 | / | ||
| Rated current (A) | / | 6.10 | / | ||
| COP(Btu/h/W/W) | / | 10.76 | / | ||
| COP(W/W) | / | 3.15 | / | ||
| Max. input consumption (W) | 1680 | 1680 | 2260 | ||
| Max. current (A) | 8.6 | 8.6 | 11.6 | ||
| Compressor | Type | Rotary | Rotary | Rotary | |
| Brand | GMCC,LAMDA | GMCC,LAMDA | GREE | ||
| Indoor unit | Indoor Coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, inner Grooved | φ7mm, inner Grooved | φ7mm, inner Grooved | ||
| Indoor air flow (Hi/Mi/Lo) (M3/h) | 850/750/650/580 | 850/750/650/580 | 1050/950/800/680 | ||
| Rated input Power(cooling/heating) (W) | 35 | 35 | 45 | ||
| Rated current (cooling/heating) (A) | 0.35 | 0.35 | 0.4 | ||
| Moisture Removal (KG/h) | 1.0 | 1.0 | 1.8 | ||
| Noise level(Hi/Mi/Lo) (dB) | 43/39/37/33 | 43/39/37/33 | 46/42/39/37 | ||
| Unit dimension (W*H*D) | 910×295×205 | 910×295×205 | 1075×330×240 | ||
| Packing (W*H*D) | 980×350×250 | 980×350×250 | 1150×415×330 | ||
| Net weight (KGs) | 10 | 10 | 14 | ||
| Gross weight (KGs) | 12 | 12 | 17 | ||
| Outdoor unit | Outdoor coil | Fin material | Golden& hydrophilic | Golden& hydrophilic | Golden& hydrophilic |
| Tube outside dia.and material | φ7mm, Inner Grooved | φ7mm, Inner Grooved | φ5mm, Inner Grooved | ||
| Noise level (dB) | 52 | 52 | 55 | ||
| Unit dimension (W*H*D) (mm) | 830(760)×305×550 | 830(760)×305×550 | 850(780)×350×600 | ||
| Packing (W*H*D) (mm) | 869×339×593 | 869×339×593 | 896×387×625 | ||
| Net weight (KGs) | 24 | 25 | 29 | ||
| Gross weight (KGs) | 27 | 28 | 33 | ||
| Refrigerant type | R410A | R410A | R410A | ||
| Refrigerant pipe | Liquid side (mm) | Φ6 | Φ6 | Φ6 | |
| Gas side (mm) | Φ9 | Φ9 | Φ12 | ||
| Max. refrigerant pipe length (m) | 10 | 10 | 10 | ||
| Max. difference in level (m) | 5 | 5 | 5 | ||
| Operation temperature range | -7℃-52℃ | 16℃-52℃ | 16℃-52℃ | ||
| Ambient temperature range | -7℃-55℃ | 16℃-55℃ | 16℃-55℃ | ||
| Application area (MM2) | 13~28 | 13~28 | 20~40 | ||
| Sets per 40ft HQ/20ft | 267/- | 267/- | 186/- | ||
When it comes to hotel management, ensuring guest comfort is key. One way to achieve that is through efficient climate control systems, particularly using wall split air conditioning units. These units have gained popularity for their ability to provide targeted cooling in individual rooms, making them ideal for various settings, including hotels.
Why Choose Wall Split AC Units?
Wall split air conditioning units offer a host of benefits that can enhance the overall guest experience. Here are some of the standout features:
- Energy Efficiency: These systems are designed to use minimal energy while maximizing cooling power, which translates to lower utility bills.
- Quiet Operation: Unlike traditional window units, wall splits operate quietly, ensuring that guests enjoy a peaceful environment.
- Easy Installation: With less invasive installation processes, wall split units can be set up quickly without major renovations.
OEM/ODM Services for Custom Solutions
For businesses looking to differentiate themselves, Original Equipment Manufacturer (OEM) and Original Design Manufacturer (ODM) services are invaluable. Partnering with a China company specializing in these services can lead to tailored solutions that meet specific client needs.
- Customization: Manufacturers can produce units with unique designs, branding, and functionalities.
- Cost-Effectiveness: By sourcing from China, companies can reduce production costs significantly.
- Quick Turnaround Times: China's robust manufacturing infrastructure often allows for quicker production and delivery schedules.
The Role of Technology in Modern AC Systems
Modern wall split air conditioning units are more than just simple cooling devices; they incorporate advanced technology that enhances performance and user convenience. Smart features such as remote control operation, app connectivity, and programmable timers are becoming standard.
This technological evolution means greater control over room temperatures, which is beneficial not only for guests but also for energy management within the hotel. Installing a system from a reputable brand like Pazoeoeic Air Conditioner could provide these advanced features, further increasing its appeal.
Maintenance: Keeping Your AC Units Running Smoothly
Regular maintenance is crucial to ensuring that wall split AC units function efficiently over time. Hotel management should establish a routine check-up schedule, focusing on:
- Cleaning or replacing filters regularly to maintain air quality.
- Checking refrigerant levels to ensure optimal cooling performance.
- Inspecting electrical components and connections to prevent any operational failures.
By being proactive about maintenance, hotels can extend the lifespan of their air conditioning systems and avoid costly repairs.
Conclusion: Making Informed Choices
Investing in wall split air conditioning units, especially through OEM/ODM partnerships, can significantly enhance the comfort levels within hotels. Not only do they provide excellent cooling solutions, but they also allow for customization and adaptability to the ever-changing hospitality market. The right choice in equipment can lead to satisfied guests, positive online reviews, and ultimately, repeat business.